Support a variety of flow path collocation which meets the needs of different customers. RUNZE patented Sapphire valve rotor and stator, anti-corrosion and high-pressure, high-temperature resistance, high wear resistance, biocompatible and suitable for a variety of special media. High efficiency and maintenance-free stepper motor drive system via RS232/RS485/CAN Small footprint suits limited spaces. Widely used in environmental analysis instruments, laboratory analyzers, medical analysis equipment, and chromatographic analyzers, etc.

| Configuration | 6/8/10 port | 12 port | 16port |
| Orifice | 1.2mm | 1.0mm | 1.0mm |
| Dead Volume | Port-to-Port 27.5μl Dead Volume 5.41μl | Port-to-Port 22.43μl Dead Volume 6.08μl | Port-to-Port 33.68μl Dead Volume 10.4μl |
| Wetted material | PCTFE, Sapphire rotor/stator | ||
| Pressure rating | 0-1Mpa (air) / 0-1.6Mpa (water) | ||
| Origin detection | Auto reset to initial position when powered on (this function can be opened or closed) | ||
| Liquid temperature | 0-150℃ | ||
| Connection | 1/4-28UNF | ||
| Replaceable parts | Stator replaceable, sealed rotor irreplaceable | ||
| Transposition | Random start to any specific port | ||
| Driver | Non-optional | ||
| Valve drive | ≤2s/circle | ≤2s/circle | ≤3.3s/circle |
| Baud rate | RS232/RS485: 9600bps, 19200bps, 38400bps, 57600bps, 115200bps CAN: 100Kbps, 200Kbps, 500Kbps, 1Mbps | ||
| Address & Parameter setting | Via communication | ||
| Power supply | DC24V/3A | ||
| Max. power | 25W | ||
| Operating temperature | -10℃~+50℃ | ||
| Operating humidity | <80% relative humidity, non-condensing | ||
| Dimension (L*W*H) | 60*51*150mm | 60*51*160.5mm | 60*51*179.5mm |
| Net Weight | 0.73kg | 0.86kg | 1.02kg |

1. Center port is public port, valve switch to specific port by programming control
2. Wetted material - PCTFE valve head and sapphire valve rotor and stator, non-metal, anti-corrosive, anti-high tempera-ture, wear resistance
3. Flow configuration - 6/8/10/12/16 port to meet different applications
4. Reset position - SV-07 valve resets by CCW (non-changeable), rotor stays between port 1 and maximum port, and the public port disconnected with any port when valve at reset status
5. OEM service - RUNZE supports special flow path design and customize, and its flow path configuration can meet the most common applications. RUZNE already declared the patent of a typical cross-contamination-free flow path solution, widely used in various analysis industries, and can provide overall flow path solutions for different needs of customers